Mornsun A_D-2W & B_D-2W series 2W isolated unregulated single or dual output DC-DC module power supplies for distributed power systems.
The Mornsun A_D-2W & B_D-2W series are 2W fixed-input, isolated, unregulated DC-DC module power supplies with single or positive/negative dual outputs. They are designed for distributed power systems on circuit boards where the output must be isolated from the input, including pure digital circuits, low-frequency analog circuits, and IGBT driver circuits.
The document covers product selection tables, input and output characteristics, general and environmental characteristics, EMC recommended circuits, characteristic curves, package dimensions, pin configurations, test methods, and design and application references including capacitive load tables and output regulation and protection circuits. This manual is written in Chinese.
| Rated power | 2 W |
|---|---|
| Efficiency | Up to 86% |
| Isolation voltage | 1000 VDC |
| Operating temperature range | -40°C to +85°C |
| Output power range | 0.2 to 2 W |
| Output voltage balance (dual output) | ±0.5% typ., ±1.0% max |
| Ripple and noise | 100 mVp-p typ., 150 mVp-p max |
| Short circuit protection | 1 second |
| Insulation resistance | 1000 MΩ min at 500 VDC |
| Switching frequency | 75 KHz typ. at full load |
| Mean time between failures | 3500 K hours at 25°C |
| Storage temperature | -55°C to +125°C |
| Case material | Black flame-retardant heat-resistant plastic (UL94-V0) |
| EMI conducted disturbance | CISPR22/EN55022 CLASS A |
| ESD immunity | IEC/EN61000-4-2 Contact ±8KV perf. Criteria B |
| Minimum load requirement | 10% of rated load |
The A_D-2W series provides positive/negative dual output, while the B_D-2W series provides single output.
The isolation voltage is 1000 VDC and the operating temperature range is -40°C to +85°C.
The output load must not be less than 10% of the rated load. If lower power is needed, a resistor equivalent to 10% of rated power can be added in parallel, or a lower power series such as A_D-1W/B_D-1W can be selected.
No. The document states that the product cannot be used in parallel and does not support hot plugging.