The Money Controls SR5 MechToolTM Manual provides step‑by‑step instructions for diagnostics, token selection, mode control and other features of the SR5 device.
This manual describes the MechTool™ programming feature of the SR5, explaining how to use the program button, diagnostic pins and rotary switch to configure the unit. It includes safety notes, a diary of changes, and detailed procedures for each diagnostic and configuration mode.
Key sections cover diagnostics (inhibit/accept line test, solenoid and inductive sensor flash test, opto test), token selection and disabling, mode control, routing control, Teach & Run™ token handling, and window tuning. Flow charts and tables illustrate the required switch positions and LED indications for each operation.
Turn the rotary switch to position 0, press and hold the program button until the LED turns red, then release the button; the LED will return to green.