Installation guide for the MONDOLUX MK04SS 3-circuit surface-mounted power track, including load capacity, suspension points, and wiring diagrams.
This guide covers installation of the MONDOLUX MK04SS Power Track 3-Circuit Surface Mounted system. It states that installation must be carried out by a licensed electrician according to local and national wiring regulations, and that only genuine Mondolux parts and accessories are to be used.
The guide also provides load capacity, suspension and surface-mounted fixing point information, and wiring diagrams. The system is rated for indoor use only in a dry and dust-free space and has an IP20 rating.
| System rating | 400V/16A 3-phase (11 kW) or 1-phase 3-circuit 230V/16A (3×3.7 kW) |
|---|---|
| IP rating | IP20 |
| Use environment | Indoor use only, dry and dust-free space |
| Maximum load capacity | 10 kg/m or 2 kg every 200 mm |
| Maximum distance between suspension points | 2000 mm |
| Maximum recommended suspension distance for 10 kg load | 1000 mm |
| Fastener load capability | Up to 10 kg/m |
Installation must be carried out by a licensed electrician according to local and national wiring regulations.
No, it is for indoor use only in a dry and dust-free space.
The maximum load capacity is 10 kg per metre, or 2 kg every 200 mm.
The maximum distance between suspension points is 2000 mm.