The manual provides safety, installation, operation, maintenance, troubleshooting, and specifications for MKS Baratron® Type 622A‑629A absolute pressure…
This instruction manual covers all aspects of the MKS Baratron® absolute pressure transducers, including safety procedures, unpacking, installation, wiring, and setup. It also explains the sensor operation, signal conditioning, and external zero adjustment for the various model variants.
Appendices list detailed product specifications, model‑code explanations, and a troubleshooting chart. The document is organized with a table of contents, figures, tables, and an index for quick reference.
| Accuracy (non-linearity, hysteresis, non‑repeatability) | 0.25% of Reading |
|---|---|
| Ambient operating temperature range | 20° to 50° C |
| Full Scale Range (Torr) | 1, 2, 10, 100, 1K |
| Input required | ±15 VDC (±5%) @ 35 mA |
| Output | 0 to +10 VDC into ≥ 10 kΩ load |
MKS Instruments warrants the equipment for two years from the date of shipment.
MKS recommends periodic calibration typically every 6 to 12 months to ensure accurate readings.
The warranty is void if the product is installed using single or double metal ferrule compression type vacuum fittings.