User manual for Minitrol HT-Series and JT-Series reverse osmosis systems covering installation, operation, maintenance, and troubleshooting.
This user’s manual covers the HT-Series and JT-Series reverse osmosis systems. It outlines installation, operation, maintenance, and troubleshooting details for sustained system performance.
The document includes feed water and operating specifications, rejection and recovery formulas, plumbing and electrical requirements, membrane element information, initial start-up, flushing, storage, and warranty information.
| Feed Temperature | 40–85°F |
|---|---|
| System Inlet Pressure | 45–85 PSIG |
| Maximum Operating Pressure | 150 PSIG nominal at 77°F |
| Maximum SDI Rating | < 3 |
| Maximum Turbidity | 1 NTU |
| Maximum Free Chlorine and/or Chloramines | 0 PPM |
| pH (continuous) | 3–11 |
| pH (cleaning - 30 min.) | 2–12 |
| NaCl Rejection | up to 98.5% |
| Membrane Type | Thin Film Composite (TFC) Low Energy |
The manual lists a feed temperature range of 40–85°F.
The maximum free chlorine and/or chloramines level is 0 PPM.
Change it once a month or when a 10–15 psi differential exists between the two pre-filter gauges.
Turn off the unit, shut off the feed water, and disconnect the electrical power.