Meiruike RK Series Variable Frequency Power Supply User Manual

Manual for the Meiruike RK series variable frequency power supply covering precautions, capacity selection, panel controls, specifications, operation and…


Meiruike RK Series Variable Frequency Power Supply User Manual - cover page
Brand
MEIRUIKE
Category
Other Electronics
Document type
User Manual
Language
Chinese
Pages
9
File format
PDF
File size
245 KB
Published
11 November, 2026
Updated
11 November, 2026
MD5 checksum
1CECA73B349AE9A7321F761D8C0CFE4D

About this manual

This manual describes the RK series variable frequency power supply made by Shenzhen Meiruike Electronic Co., Ltd., a unit that provides a pure sine wave output as a standard AC source. It covers precautions, how to choose the power supply capacity for resistive, inductive, rectifier and mixed loads, the front-panel controls and displays, device specifications, step-by-step operation and troubleshooting of common faults.

The document also explains HI/LO output voltage range switching, fixed and adjustable output frequency settings (45–70 Hz), restarting with the RESET switch after overload or short-circuit protection trips, and an appendix table listing input currents, protection switch ratings, wire sizes and output currents for 220 V single-phase and 380 V three-phase models from 1 kVA to 90 kVA. This manual is written in Chinese.

What's inside

  • Precautions
  • Power supply capacity selection method
  • Front panel diagram and description
  • Device specifications
  • Operating steps
  • Operation instructions
  • Troubleshooting
  • Appendix 1: input current, breaker and wire size table

Specifications

Circuit typeIGBT PWM pulse width modulation
Output capacity0.5 kVA (checked on the RK-5000 specification sheet)
Input voltageSingle-phase 2-wire 220 V ±10%, 50 Hz
Input frequency50 Hz / 60 Hz ±5%
Output voltage0–300 V continuously adjustable; HI/LO ranges: HI 0–300 V, LO 0–150 V
Output frequencyFixed 50 Hz, 60 Hz, 2F/4F, 400 Hz; adjustable 45 Hz–70 Hz
Load regulation≤0.5%
Frequency stability≤0.1%
Waveform distortion≤2% (measured under resistive load)
Efficiency≥85% at full load
ProtectionOverload, short-circuit, over-voltage/current, over-temperature protection and buzzer alarm
Operating environmentTemperature 0–40 °C, relative humidity 0–90%
Display resolutionVoltage 0.1 V, current 0.01 A, frequency 0.1 Hz

Frequently asked questions

How do I choose the power supply capacity for a resistive load?

For a resistive load the power supply capacity is 1.1 times the load power.

What should I do if the buzzer alarms and pressing RESET does not clear it?

Check for a short circuit in the load connected to the output, replace a faulty RESET button, or move the unit to a place with better ventilation.

How do I set the output frequency to 55 Hz?

Turn the selector switch to [VAR] and turn the VAR adjustment knob until the frequency display shows 55.

What happens after the input power switch is turned on?

After about 20 seconds the buzzer sounds; press the [RESET] switch on the panel and the output voltage is then supplied.

What are the HI and LO output voltage ranges and how do I switch between them?

HI is 0–300 V and LO is 0–150 V; switch off the connected load and the output protection switch before changing the HI/LO selector.