MEGGLE MicroceLac 100 technical leaflet on this co-processed excipient of alpha-lactose monohydrate and microcrystalline cellulose for direct compression.
This MEGGLE technical leaflet describes MicroceLac 100, a co-processed excipient made by spray-drying alpha-lactose monohydrate and crystalline cellulose together. The leaflet states that the grade consists of 75% alpha-lactose monohydrate and 25% microcrystalline cellulose, with the chemical properties of each component retained, and that it was developed to provide the flowability and compressibility needed for direct compression.
The document covers the product description and basic information on direct compression, benefits, applications (direct compression, dry granulation and capsule filling), regulatory and quality information, particle size distribution by laser diffraction and air-jet sieving, batch-to-batch consistency, sorption isotherms, SEM images, flowability and adherence capacity data. This manual is written in Japanese.
| Composition | 75% alpha-lactose monohydrate and 25% microcrystalline cellulose |
|---|---|
| Particle size, air-jet sieving, < 32 µm | NMT 15% specified / 7% typical |
| Particle size, air-jet sieving, < 160 µm | 45–70% specified / 59% typical |
| Particle size, air-jet sieving, < 250 µm | NLT 90% specified / 95% typical |
| Flowability index | 2 mm (physical blend: 9 mm) |
| Angle of repose | 34° |
| Bulk density | 460 g/l |
| Tapped density | 580 g/l |
| Hausner ratio | 1.26 |
| Carr's index | 20.69% |
| Quality certification of the Wasserburg production site | DIN ISO 9001:2015 |
It consists of 75% alpha-lactose monohydrate and 25% microcrystalline cellulose, produced by spray-drying both components together; the chemical properties of each component are retained.
It was developed for direct compression and can also be used for dry granulation (roller dry, slug) and capsule filling.
The leaflet states that the alpha-lactose monohydrate and crystalline cellulose used meet the requirements of the Ph. Eur., USP-NF and JP monographs.
The flowability index is 2 mm for MicroceLac 100 versus 9 mm for the physical blend, indicating better flow.