Master Builders Solutions MasterSeal AWB 971 FIB Reinforced Non-Woven Polyester Fabric Technical Data Guide

Technical data guide for MasterSeal AWB 971 FIB reinforced non-woven polyester fabric used with MasterSeal AWB 660/665 or AWB 660 I barriers.


Master Builders Solutions MasterSeal AWB 971 FIB Reinforced Non-Woven Polyester Fabric Technical Data Guide - cover page
Brand
Master Builders Solutions
Document type
Product Leaflet
Language
English
Pages
2
File format
PDF
File size
271 KB
Published
14 November, 2026
Updated
14 November, 2026
MD5 checksum
297DBAD31F2EE7EC30E8673FBC23B4E3

About this manual

MasterSeal AWB 971 FIB is a reinforced non-woven polyester fabric used with MasterSeal AWB 660/MasterSeal AWB 665 or MasterSeal AWB 660 I air/water-resistive barriers by Master Builders Solutions. It reinforces these barriers over acceptable rough openings, sheathing joints, and transitions in above grade construction.

The guide covers packaging sizes, shelf life, shipping and storage, uses, limitations, application steps, health and safety information, technical support, and a limited warranty notice.

What's inside

  • Packaging
  • Shelf Life
  • Shipping and Storage
  • Description
  • Uses
  • Limitations
  • Application
  • Health, Safety and Environmental
  • Technical Support
  • Limited Warranty Notice

Specifications

4 in roll size4 in x 180 ft (101.5 mm x 54.8 m)
6 in roll size6 in x 180 ft (152.4 mm x 54.8 m)
9 in roll size9 in x 180 ft (228.5 mm x 54.8 m)
Fabric weight2.45 oz/yd2 (83 g/m2)
Shelf life2 years when stored in the original unopened container and stored as directed
Minimum lap at intersections63.5 mm (2 1/2 in)
Evaluation reportsICC-ES ESR-3209 and ESR-3310
Test standardsICC-ES AC212, AC 148, and ASTM E2357

Frequently asked questions

What is MasterSeal AWB 971 FIB used with?

It is designed for use with MasterSeal AWB 660/MasterSeal AWB 665 or MasterSeal AWB 660 I air/water-resistive barriers to reinforce rough openings, sheathing joints, and transitions.

How should MasterSeal AWB 971 FIB be stored?

Store it in a cool, dry place protected from extreme heat, moisture, cold, and direct sunlight, and protect it from physical damage during transportation and installation.

What is the minimum lap at intersections?

Lap MasterSeal AWB 971 FIB 63.5 mm (2 1/2 in) minimum at intersections.

How is MasterSeal AWB 971 FIB applied?

Place and center the fabric over wet MasterSeal AWB 660/665 or AWB 660 I, embedding and completely saturating it, then allow it to dry to the touch before applying the barrier to the entire wall surface.