Manostats PST pressure transmitters: technical features, part numbers, electrical connections, autozero, DIP switch and threshold settings, mounting and…
This document covers the Manostats PST range of pressure transmitters (manostats): PST11, PST12, PST13 with ranges from -100/+100 Pa to -10 000/+10 000 Pa, and PST14 and PST15 with ranges of -500/+500 mbar and -2000/+2000 mbar. It lists the technical features of the ABS V0 IP65 housing, the LCD display, the pressure connections, the RCR relay output and the 24 Vac/Vdc power supply, and explains how to build a part number.
It then describes the electrical connections, the autozero procedure, and the settings made with the internal DIP switches and the front button: unit of measurement, alarm activation, rising edge, falling edge or monitoring mode, threshold values, hysteresis and time-delays up to 600 seconds. Configuration through the optional LCC-S software, wall mounting, maintenance and available accessories are also covered.
| Housing material | ABS V0 as per UL94 |
|---|---|
| Protection | IP65 |
| Display | LCD, 10 digits, 50 x 17 mm |
| Weight | 143 g |
| Measuring range | -100/+100 Pa up to -2000/+2000 mbar (according to model) |
| Accuracy (PST11) | ±1% of reading ±2 Pa |
| Response time | 1/e (63%) 0.3 s |
| Type of fluid | Air and neutral gases |
| Operating temperature | 0 to +50 °C |
| Storage temperature | -10 to +70 °C |
| Power supply | 24 Vac/Vdc ±10 % |
| Consumption | 2 VA |
| Output | RCR relay 3 A / 230 Vac |
Unplug the two pressure connection tubes and press the "Autozero" key. On the PST11 transmitter it is not necessary to unplug the tubes.
No. To configure the transmitter it must not be energized; unscrew the 4 screws, open the housing and set the DIP switches, then power it up.
The time-delay values can be set up to 600 seconds.
Mount the ABS plate on the wall with Ø6 mm drilling (screws and pins are supplied), insert the transmitter on the fixing plate and rotate the housing clockwise until a click is heard.