Luxfer Graphic Arts 12-step process guide for magnesium photo engraving plates, covering storage, exposure, developing, descum, etching and post-etch washing.
This four-page guide from Luxfer Graphic Arts, document MGEN1001-2, sets out 12 steps for processing Luxfer Precision magnesium photo engraving plates. It walks through storage, artwork inspection, exposure with a Stouffer 21-Step Sensitivity Guide, developing by hand or automatic processing, post developing, touch-up, weighing, descum, plate protector, etching, bath replenishment and post-etching wash.
The guide gives separate handling notes for Hydro-Solve® and Red Top™ plates, including developer mixing ratios, descum formulas and drying or curing temperatures. A final page lists the MegaEtch™ equipment formats, available gauge range and standard sheet formats, plus the wider Luxfer photo engraving product range and regional sales contacts.
| Gauge range | 1.00 mm / .040” through 9.53 mm / .375” |
|---|---|
| Standard formats | 457 x 610 mm / 18 x 24” through 762 x 1016 mm / 30 x 40” |
| Etching equipment | MegaEtch™ 120L, MegaEtch™ 60L, MegaEtch™ 45L (other formats available) |
| Red Top™ exposure step | Solid Step 6-8 on a Stouffer 21-Step Sensitivity Guide |
| Hydro-Solve® exposure step | Step 9-11 on a Stouffer 21-Step Sensitivity Guide |
| Scale accuracy for plate weighing | Nearest 7 gram / ¼ ounce |
| Red Top™ post-develop heating | 120-150oC (250-300oF) for at least two minutes |
Mix one part Hydro-Solve® Developer with four parts water, and use it at room temperature or heated.
A light descum with a 1% to 2% solution of nitric acid mixed with water is recommended, without over-descumming.
Expose Red Top™ Plates to a solid Step 6-8 on a Stouffer 21-Step Sensitivity Guide, using the higher end for fine detail work.
An application of Express Guard® or Visko® Plate Protector/Wetting Agent/Gum Arabic Solution is recommended before etching.