Fitting guide for the Lorient LAS8002 SI drop seal, covering supplied parts, tools, face-fixed and semi-mortised installation, adjustment, and cut-back sizes.
This fitting guide covers installation of the Lorient LAS8002 SI drop seal. It lists the supplied parts and required tools, then gives face-fixed and semi-mortised installation steps, including cutting, fixing, striker button placement, and adjustment.
The guide also provides cut-back sizes for different seal lengths, installation notes, and fire-door application information for wood, composite, and steel or hollow metal doors.
| Door bottom to sill gap | 3-13 mm |
|---|---|
| Semi-mortised rebate | 35 mm deep x 14 mm wide |
| Aluminium section cut allowance | Measured length minus 8 mm |
| Ferrules supplied | 335-535 mm lengths only |
| Fire door rating, wood or composite doors | Up to 1.5 hours |
| Fire door rating, steel or hollow metal doors | Up to 3 hours |
| Pressure test | Positive pressure-tested |
The guide lists a tape measure, pencil or marker, saw, screwdriver, drill with a 2.5 mm bit, router with cutting bit, and scissors, knife, or snips.
The seal should be positioned with a maximum 13 mm gap and a minimum 3 mm gap between the door bottom and the sill.
A 35 mm deep by 14 mm wide rebate should be cut into the bottom of the door.
Pull out the actuator button, hold the threaded rod firmly, and turn the button clockwise to reduce movement or anti-clockwise to increase movement.