Lorient LAS8002 SI Drop Seal Fitting Guide

Fitting guide for the Lorient LAS8002 SI drop seal, covering supplied parts, tools, face-fixed and semi-mortised installation, adjustment, and cut-back sizes.


Lorient LAS8002 SI Drop Seal Fitting Guide - cover page
Brand
Lorient
Category
Other products
Document type
Installation Guide
Language
English
Pages
1
File format
PDF
File size
240 KB
Published
21 November, 2026
Updated
21 November, 2026
MD5 checksum
08D5D2AD2B13C2AAB91D8EC3FB5E1943

About this manual

This fitting guide covers installation of the Lorient LAS8002 SI drop seal. It lists the supplied parts and required tools, then gives face-fixed and semi-mortised installation steps, including cutting, fixing, striker button placement, and adjustment.

The guide also provides cut-back sizes for different seal lengths, installation notes, and fire-door application information for wood, composite, and steel or hollow metal doors.

What's inside

  • Contents
  • Tools required
  • Face-fixed installation
  • Semi-mortised installation
  • Cut back sizes
  • Notes

Specifications

Door bottom to sill gap3-13 mm
Semi-mortised rebate35 mm deep x 14 mm wide
Aluminium section cut allowanceMeasured length minus 8 mm
Ferrules supplied335-535 mm lengths only
Fire door rating, wood or composite doorsUp to 1.5 hours
Fire door rating, steel or hollow metal doorsUp to 3 hours
Pressure testPositive pressure-tested

Frequently asked questions

What tools are required to fit the Lorient LAS8002 SI drop seal?

The guide lists a tape measure, pencil or marker, saw, screwdriver, drill with a 2.5 mm bit, router with cutting bit, and scissors, knife, or snips.

What gap should be left between the door bottom and the sill?

The seal should be positioned with a maximum 13 mm gap and a minimum 3 mm gap between the door bottom and the sill.

What rebate size is needed for semi-mortised installation?

A 35 mm deep by 14 mm wide rebate should be cut into the bottom of the door.

How is the seal movement adjusted?

Pull out the actuator button, hold the threaded rod firmly, and turn the button clockwise to reduce movement or anti-clockwise to increase movement.