Loewen LiftSlide door installation guide covering site preparation, opening requirements, sill pans, and FASTrack system notes.
Loewen LiftSlide Door Installation Guide covers installation and site preparation for Loewen LiftSlide door systems. It is written for construction professionals with proven competency installing doors for large openings, and it recommends certified installers; the text says certified installation is required to meet warranty requirements.
The guide addresses building envelope preparation, rough opening requirements, header deflection limits, sill pan installation, and the adjustable FASTrack system. It also notes that sill pans must be used in every LiftSlide installation and that installers must work from the provided drawings to prepare the opening.
| Maximum header deflection | 1/8 inch along the unsupported length once fully loaded |
|---|---|
| Recommended finish floor depression depth | 2 1/2 inches |
| Sill pan minimum end dam | 6 inches |
| Sill pan interior upturn leg | 1/2 inch |
| Sill pan exterior down turn leg | 2 inches |
| Sill pan options | Rigid, flexible, or liquid |
| Configuration shown | Three panel, jamb, 1 1/2 inch flush sill |
Yes. The guide states that all systems are required to be installed by a certified installer to meet warranty requirements.
Structural headers must allow deflection no greater than 1/8 inch along the unsupported length once the header is fully loaded.
Yes. Sill pans must be used in every installation of a Loewen LiftSlide system.
Seal and finish all panels and wood surfaces, especially the edges, before installation.