Liye Technology Multifunction Power Meter User Manual

Chinese user manual for the Liye Technology multifunction power meter, covering functions, specifications, installation and wiring, and keypad programming.


Liye Technology Multifunction Power Meter User Manual - cover page
Brand
立业科技
Category
Other
Document type
User Manual
Language
Chinese
Pages
2
File format
PDF
File size
374 KB
Published
17 November, 2026
Updated
17 November, 2026
MD5 checksum
58791E20A783CF419CAE383345FB3B86

About this manual

This manual describes the Liye Technology multifunction power meter, a combined ammeter, voltmeter, wattmeter, power factor meter and energy meter intended for 50/60 Hz power supply systems. It measures and displays three-phase voltage and current, active and reactive power, power factor, frequency and accumulated active and reactive energy, and connects to a monitoring network through an RS485 interface using the ModBus RTU protocol.

The document gives the main technical specifications, the panel cutout and installation steps, and wiring notes for the auxiliary power supply and input signals. It also explains the display pages and the four-key programming procedure, including the setup, input and communication menus and a table of the programming characters and settings. This manual is written in Chinese.

What's inside

  • Function overview
  • Main technical specifications
  • Installation and wiring
  • Display and key operation
  • Programming setting character table
  • Usage and ordering notes
  • Display diagram explanation
  • Wiring methods

Specifications

Wiring mode3P3L (three-phase three-wire) or 3P4L (three-phase four-wire)
Rated current inputAC 1 A, 5 A
Rated voltage inputAC 100 V, 220 V, 380 V
CommunicationRS485 serial interface, ModBus protocol, RTU format, 4800 or 9600 bps
Current measurement range and accuracy0 to 5 A, 0.5 %
Voltage measurement range and accuracy0 to 450 V, 0.5 %
Frequency measurement45 to 60 Hz, ±0.1 Hz
Insulation strengthIEC 60255-5, 2 kVrms for 1 min
Operating temperature0 °C to +55 °C
Operating power supply and consumptionAC 85 to 265 V or DC 100 to 275 V, 8 VA
Panel and cutout dimensionsPanel 96 × 96 mm, cutout 91 × 91 mm, depth 88 mm
Operating altitudeBelow 3000 m

Frequently asked questions

What is the factory default programming password?

The meter is shipped with the password set to 0001.

What communication interface and protocol does the meter use?

It uses an RS485 serial interface with the ModBus protocol in RTU format, at 4800 or 9600 bps.

What must be done before removing the current input wiring connected to a CT?

The CT primary circuit must first be disconnected or the secondary circuit shorted.

What accessories are supplied with the meter?

One set of mounting accessories, one manual and one certificate of conformity.

Download PDF (374 KB)