This manual covers the selection, installation, electrical wiring, and maintenance of the LianCe U-AL-10-LCCN A-Series online infrared thermometer.
The LianCe U-AL-10-LCCN is an integrated online infrared thermometer designed for non-contact surface temperature measurement. It features a stainless steel housing, a standard M18×1 thread for mounting, and various optional accessories like air purging kits and cooling sleeves to suit different operating conditions. The device operates in a temperature range of -60 to 2400°C and supports multiple output signals including 4-20mA, 0-5V, and 0-10V. This manual is written in Chinese.
| Protection Rating | IP65 (NEMA-4) |
|---|---|
| Operating Temperature | 0 ~ 60°C |
| Storage Temperature | -20 ~ 80°C |
| Relative Humidity | 10 – 95% (no condensation) |
| Standard Cable Length | 2m |
| Working Power Supply | 12~24 VDC |
| Spectral Range | 8 ~ 14 µm |
| Optical Resolution | 4:1 to 100:1 |
| Response Time | 300ms (default) |
| Measurement Accuracy | ±1% or ±1°C (whichever is greater) |
| Mounting Thread | M18×1 |
The device can operate in an ambient temperature range of 0 to 60°C.
The thermometer supports 0-5V, 0-10V, and 4-20mA output signals.
Use lens paper dipped in anhydrous alcohol to wipe the lens if it is dirty.
The instrument has a 12-month warranty period from the date of manufacture.