The Leica MS50/TS50/TM50 user manual provides safety directions, setup, operation, and technical data for these surveying instruments.
This manual introduces the MS50/TS50/TM50 series, outlines safety directions, and describes the system components, user interface, and operating principles. It also explains how to connect the instrument to a PC, manage power functions, batteries, and memory devices.
Technical data sections detail laser specifications, measurement ranges, accuracy, and environmental conditions. The document concludes with care and transport guidelines, a software licence agreement, and an index for quick reference.
| Laser wavelength | 650 nm – 690 nm |
|---|---|
| Maximum average radiant power | 0.33 mW |
| Pulse repetition frequency (PRF) | 100 MHz – 1.1 MHz |
| Beam divergence | 1.5 mrad × 3 mrad |
| Laser classification | Class 1 |
| Precise measurement accuracy | 0.6 mm + 1 ppm |
The manual uses DANGER, WARNING, CAUTION, and NOTICE to indicate different hazard levels.
The instruments are classified as Laser Class 1.
The laser operates in the 650 nm to 690 nm wavelength range.