This manual provides installation procedures, PLC and Macro configuration, and integration instructions for third-party laser trackers with the LEANTEC…
This document serves as an application guide for the LEANTEC laser positioning and tracking system. It details the installation workflow, including modifying PLC and alarm files, and uploading necessary resources to the controller. The guide covers the integration of third-party laser trackers that support Modbus TCP communication, providing specific configuration steps for custom setups. This manual is written in Chinese.
| Communication Protocol | Modbus TCP |
|---|---|
| Data Response Time | 50ms |
| Coordinate Unit | 0.01mm |
| G-Code Range | G510.0~G510.29 |
The tracker must support Modbus TCP communication, allow IP address modification, and be able to read/write specific data points like laser line status and XYZ coordinates within 50ms.
If the system expects 0.001mm but the tracker provides 0.01mm, the coordinate values must be multiplied by 10 during data processing.
If the recognition fails after exceeding the retry count, the system will trigger Macro 10013 alarm.