LDM 200 Line Control and Shut-off Valves in Seismic Version

Seismic-resistant control and shut-off valves for industrial applications, featuring material specs, flow characteristics, and actuator options.


LDM 200 Line Control and Shut-off Valves in Seismic Version - cover page
Brand
LDM
Document type
Product Leaflet
Language
English
Pages
24
File format
PDF
File size
2.1 MB
Published
05 November, 2026
Updated
05 November, 2026
MD5 checksum
167FDCBB9CD4E49FEB68130A2EFCD387

About this manual

This document details LDM’s 200 Line seismic-resistant control and shut-off valves, designed for regulation and shut-off of process liquid flow. Valves meet seismic class 1b standards for up to 30 m.s² response spectrum. Materials, flow characteristics, and actuator options are specified. Installation guidelines include orientation, strainer requirements, and temperature limits.

Valves are available in various materials including stainless steel and cast steel, with seat and packing options for different media and temperatures. Flow characteristics include linear, equal-percentage, LDMspline, and parabolic. Actuators include hand wheel and electric types with specified linear forces. Seismic resistance and leakage rates are defined by international standards.

What's inside

  • Seismic Resistance
  • Materials and Body Construction
  • Flow Characteristics and Kvs Values
  • Actuator Options
  • Installation and Orientation
  • Packing and Sealing Options
  • Temperature and Pressure Ratings
  • Seat Materials and Leakage Rates

Specifications

Seismic ResistanceClass 1b, up to 30 m.s² response spectrum, 0 to 33 Hz
Max Differential PressureUp to 4.0 MPa for perforated plugs, 1.6 MPa for standard
Flow CharacteristicsLinear, equal-percentage, LDMspline, parabolic, on-off
Leakage Rate<0.01% Kvs for shut-off valves, <0.1% Kvs for control valves

Frequently asked questions

What is the seismic resistance of the valves?

The valves meet seismic class 1b standards for up to 30 m.s² response spectrum, 0 to 33 Hz.

What are the available flow characteristics?

The valves offer linear, equal-percentage, LDMspline, parabolic, and on-off characteristics.

What is the maximum differential pressure for standard valves?

The maximum differential pressure for standard valves is 1.6 MPa.

Download PDF (2.1 MB)