The Lancer CED 400 beverage machine user manual provides safety instructions, installation steps, cleaning, troubleshooting, and specifications.
This manual is the primary reference for owners, operators, and installers of the Lancer CED 400 beverage machine. It covers safety warnings, required tools, installation procedures, system setup, and routine maintenance.
Key sections include safety and CO₂ warnings, electrical specifications, water‑pressure requirements, detailed installation checklists, cleaning and sanitizing instructions, troubleshooting guides, and full parts and wiring diagrams. This manual is written in Chinese.
| Width | 10.83 inches (275 mm) |
|---|---|
| Depth | 28.51 inches (724 mm) |
| Height | 30.04 inches (763 mm) |
| Shipping weight | 154 lbs (69.9 kg) |
| Electrical rating (115 V) | 115 VAC, 60 Hz, 12 A |
| Electrical rating (220‑240 V) | 220‑240 VAC, 50‑60 Hz, 6 A |
| CO₂ supply pressure | 70 psi min – 80 psi max |
| Carbonated water flow pressure | 25 psi min – 50 psi max |
| Noise level | < 70 dB |
| Maximum operating altitude | 16,400 ft (5,000 m) |
The machine can be powered by 115 VAC at 60 Hz drawing 12 A, or by 220‑240 VAC at 50‑60 Hz drawing 6 A.
Carbonated water supply must be set between 25 psi (0.172 MPa) minimum and 50 psi (0.345 MPa) maximum.
At least 8 inches (203 mm) of clearance must be maintained above the unit to ensure adequate airflow.