Laird Technologies OptoTEC HOT12-65-F2A-1312 Thermoelectric Module Datasheet

Laird Technologies OptoTEC HOT12-65-F2A-1312 datasheet for a miniature thermoelectric module, with features, applications, specifications and operating tips.


Laird Technologies OptoTEC HOT12-65-F2A-1312 Thermoelectric Module Datasheet - cover page
Brand
Laird Technologies
Category
electronic components
Document type
Datasheet
Language
English
Pages
2
File format
PDF
File size
354 KB
Published
18 November, 2026
Updated
18 November, 2026
MD5 checksum
98486AFE099FFE14E5DA32681C1EDF34

About this manual

The OptoTEC Series is a miniature thermoelectric module (TEM) used primarily to stabilize the temperature of sensitive optical components in telecom and photonics industries. It is assembled with Bismuth Telluride semiconductor material and thermally conductive Aluminum Oxide ceramics and is designed for lower current and lower heat-pumping applications. The series is offered in multiple configurations and surface finishing options. This product has reached end of production and is available on a limited basis; the document suggests ET12-65-F2A-1312 HiTemp ET Series as a replacement.

This datasheet lists features, applications, performance specifications, suffix options, sealing options, performance curves and a mechanical drawing. It also includes operating tips such as a 175°C maximum operating temperature and not exceeding Imax or Vmax. Custom designs are available for metallization, pretinning, ceramic patterns and solder posts, with MOQ applying.

What's inside

  • Features
  • Applications
  • Specifications
  • Performance
  • Suffix
  • Sealing Options
  • Performance Curves
  • Mechanical Drawing
  • Operating Tips

Specifications

Hot Side Temperature25 °C and 50 °C performance columns
Qmax5.3 W at hot-side 25 °C; 5.9 W at 50 °C
Delta Tmax67 °C at hot-side 25 °C; 77 °C at 50 °C
Imax1.2 A
Vmax7.4 V at hot-side 25 °C; 8.4 V at 50 °C
Module resistance5.65 ohms at hot-side 25 °C; 6.37 ohms at 50 °C
Ceramic material96% alumina ceramics
Solder construction271 °C, proprietary
Maximum operating temperature175 °C

Frequently asked questions

What is the OptoTEC Series used for?

It is primarily used to stabilize the temperature of sensitive optical components in telecom and photonics industries.

Is this product still in production?

No. It has reached end of production and is available on a limited basis only.

Is there a recommended replacement for this module?

Yes, the document suggests the ET12-65-F2A-1312 HiTemp ET Series module as a replacement.

What is the maximum operating temperature of the module?

The datasheet lists a maximum operating temperature of 175 °C.