Operation and maintenance manual for Kilews DC-type automatic non carbon-brush screwdrivers, covering safety, torque adjustment, and servicing guidelines.
This manual provides safety instructions and operational guidelines for Kilews DC-type automatic non carbon-brush screwdrivers. It includes precautions for electrical and personal safety, torque adjustment procedures, and maintenance schedules. The tool is designed for metal assembly applications and must be grounded during use. Regular inspection and servicing are required to maintain safe operation.
The manual emphasizes proper handling, including keeping the tool unplugged when changing bits, avoiding chemicals, and not exceeding torque settings. It also details grounding requirements and testing procedures to ensure safe operation and prevent electric shock.
Do not adjust the torque setting higher than 8 on the torque scale.
Every 5-6 months if used more than eight hours a day, or daily if used for more than eight hours.
Inspect tool cords periodically and if damaged, have them repaired by an authorized service facility.