Installation and user guide for the Kelda Showers BubbleSpa 95005000 thermostatic shower system, covering safety, installation, use and maintenance.
The Kelda Showers BubbleSpa 95005000 is an exposed thermostatic shower system that requires hot and cold water supplies in addition to an electrical connection. The document provides important safety information, system diagrams, a parts list, installation and electrical installation instructions, a user guide, maintenance instructions, troubleshooting and customer care details.
The guide specifies a recommended minimum water pressure of 2 bar (0.2 MPa) and a maximum of 5 bar (0.5 MPa). It states that the shower performs best between 8-12L/min and will not produce bubbles below 6L/min. Electrical requirements include a 3A switched fused spur and, in UK electric and pumped shower circuits, a 32A 30 mA RCBO.
| Minimum water pressure | 2 bar (0.2 MPa) recommended minimum |
|---|---|
| Maximum water pressure | 5 bar (0.5 MPa) |
| Recommended flow rate | 8-12 L/min for best performance |
| Minimum flow rate for bubbles | 6 L/min |
| Overhead Shower IP rating | IPX4 |
| Electrical connection | 3A switched fused spur |
| RCBO rating | 32 A, 30 mA |
| Flashing light frequency | minimum 72 Hz |
A 2 bar (0.2 MPa) system is recommended as a minimum, and the maximum water pressure is 5 bar (0.5 MPa).
No; the guide says the shower should not be installed in an outdoor environment, including sheltered areas.
Each shower must be connected to an easily accessible 3A switched fused spur.
It must be cleaned regularly with descalant to remove scale and debris.