User manual for the Jinko Solar JKS-3~6HLVS-ABI series hybrid inverter, covering installation, commissioning, operation, troubleshooting, and specifications.
The JKS-3~6HLVS-ABI series is a hybrid inverter used to store energy generated by photovoltaic cell panels or energy from the grid in a battery; energy can also be sent to the power grid for self-consumption, and the unit can be used as backup power when grid power is lost. The series includes six types: JKS-3HLVS-ABI, JKS-3.6HLVS-ABI, JKS-4HLVS-ABI, JKS-4.6HLVS-ABI, JKS-5HLVS-ABI, and JKS-6HLVS-ABI.
The manual provides product information and installation instructions for professional electrical personnel, including safety instructions, unpacking, installation, grounding, commissioning, display and button operation, communication, country setting, start-up and shutdown, fault removal, decommissioning, and product specifications. It states that the inverter can be used with lithium or lead-acid batteries, and that Jinko can only provide lithium batteries compatible with the inverter.
| Max. PV voltage | 550 V DC |
|---|---|
| PV voltage range | 120-550 V DC |
| PV Isc | 16.9 A DC*2 |
| Max. input current | 13.5 A DC*2 |
| Rated output/input power | 6000/6000 W |
| Rated output apparent power | 6000 VA |
| Nominal voltage | 230 V AC |
| Rated input/output current | 27/27 A AC |
| Nominal frequency | 50 Hz |
| Power factor range | 0.8 leading to 0.8 lagging |
| EPS rated output apparent power | 4000 VA |
| EPS rated voltage | 230 V AC |
| EPS rated output current | 17.5 A AC |
| EPS nominal frequency | 50 Hz |
| Battery voltage range | 42-59 V DC |
| Rated charging/discharging current | 85 A DC |
| Type of battery | Lithium/Lead-acid |
| Safety level | Class I |
| Overvoltage category | PV: II, AC: III, Others: I |
| Ingress protection | IP65 |
| Operation ambient temperature | -25 C to +60 C |
| Inverter topology | Non-isolated |
| Certificate No. | SAA211107 |
The JKS inverter can be used with lithium batteries or lead-acid batteries.
Wait 5 minutes before opening the upper lid or DC lid because residual voltage remains in the inverter.
The inverter has an ingress protection rating of IP65.
The service hotline is +61 1300 326 182.