User manual for the JFL IRA-50 Digital infrared sensor, covering installation, alignment, sensitivity adjustment, and safety precautions.
This manual provides instructions for installing and configuring the JFL IRA-50 Digital infrared sensor. It details alignment using an LED indicator, sensitivity adjustment via a trimpot, lens positioning, wiring, and operational precautions. The sensor operates with a 60m range indoors and 30m outdoors, with adjustable vertical and horizontal angles. Proper installation requires ensuring no obstructions interrupt the beam during alignment and avoiding direct sunlight exposure to the receiver. This manual is written in Portuguese.
| Protection Range | 60m indoor, 30m outdoor |
|---|---|
| Vertical Adjustment | ±22° |
| Horizontal Adjustment | ±90° |
| Transmitter Current | 40mA |
| Receiver Current | 20mA |
| Supply Voltage | 10 to 24Vdc or 10 to 24Vac (non-polarized) |
During mechanical alignment, the red high-brightness LED labeled 'ALINHA' should be off. If it is on, adjust until it turns off. A blinking LED indicates medium or good signal strength, while an off LED indicates optimal alignment.
Adjust the 'SENS' trimpot. Minimum sensitivity requires 500ms interruption, maximum requires 50ms interruption.
Do not install near plants or branches that may obstruct the beam. Avoid direct sunlight on the receiver. Do not install on unstable or movable surfaces. Keep away from water or dirty splashes.