This manual provides operating instructions, calibration methods, and settings for the Iraytek T Series handheld infrared thermal imager.
This user manual covers the Iraytek T Series handheld infrared thermal imager, including quick start guides, operational procedures, and detailed settings. It explains how to power the device, adjust focus modes (automatic, electric, and manual), and capture images or video. The guide also details temperature measurement calibration and parameter adjustments such as emissivity and environmental conditions. This manual is written in Chinese.
| Default Temperature Range | -20℃~150℃ |
|---|---|
| Emissivity for Insulated Tape | 0.93 |
| Company Website | www.iraytek.com |
We recommend calibrating the thermal imager once a year.
Measurements should be taken after the device has been powered on for five minutes.
The recommended emissivity for general power equipment inspection is 0.9.