Configuration guide for the Inspur G5 series storage system covering setup, safety, environment, and management tasks.
The Inspur G5 series storage manual provides step‑by‑step instructions for installing, configuring, and managing the storage system. It includes safety statements, environmental requirements, connection and power procedures, system initialization, and cluster configuration.
Detailed sections cover storage pool and volume management, host integration, local replication, and browser configuration for the management GUI. The guide also contains appendices with abbreviations, environmental specifications, and regulatory information. This manual is written in Chinese.
| Operating humidity range | 5%–95% RH, non‑condensing |
|---|---|
| Recommended storage humidity | <50% RH for long‑term storage |
| Particle contamination limit (≥0.5 µm) | ≤3,520,000 particles/m³ |
| Maximum unpowered HDD storage time | 2 months (‑40 °C ~ 70 °C) |
| BBU charging interval | At least once every 6 months |
No. Only trained service technicians are authorized to open the chassis and replace internal components.
An unpowered HDD may be stored for up to 2 months within a temperature range of –40 °C to 70 °C.
Connect the device only to a power source matching the rated input label and use voltage‑stabilizing equipment or UPS to protect against surges.