User manual for the Innowater SMC 16 salt water chlorinator, covering installation, water preparation, adding salt, operation, cleaning and specifications.
The Innowater SMC 16 salt water chlorinator user manual explains control unit and cell housing installation, water preparation, adding salt, and operation with the four-key keypad.
It also covers recommendations and warnings, manual cell cleaning, warranty and technical service, and technical characteristics.
| Salt concentration | 5-6 kg/m3 (gr/l) |
|---|---|
| pH | 7,2-7,6 (cement); 6,8-7,0 (polyester) |
| TAC | 60-100 ppm |
| TH | 15-20º French |
| Stabilizer | 20-30 ppm |
| Temperature | >10 º C |
| Factory polarity period | 8 hours |
| Production variation period | 10 minutes |
| Control unit distance from cell | 1.5 meters max. |
| Power supply | 230 VAC |
The manual specifies 5 to 6 kg of salt per cubic meter of water.
The chlorinator must stay disconnected and the filtration system should run for at least 24 hours.
The polarity applied to the cell is reversed periodically, and the factory pre-programmed period is 8 hours.
No. It must remain totally disconnected until the salt is completely dissolved.