Technical datasheet for the ifm efector LR3300 guided wave radar continuous level sensor, detailing electrical data, measuring range, and operating conditions.
The ifm efector LR3300 is a continuous level sensor utilizing guided wave radar technology. It is designed for measuring media with a dielectric constant of 20 or greater, such as water and hydrous coolants. The device features a 4-digit alphanumeric display and two LEDs for status indication.
| Dielectric constant of medium | ≥ 20 |
|---|---|
| Medium temperature | 0...80 °C |
| Tank pressure | -1...16 bar |
| Maximum Allowable Working Pressure (MAWP) | 25 bar |
| Operating voltage | 18...30 V DC |
| Current consumption | < 80 mA |
| Probe length | 100...1600 mm |
| Repeatability | ± 5 mm |
| Ambient temperature | 0...60 °C |
| Protection class | IP 67 |
It is recommended for hydrous coolants, water, and media similar to water.
No, it cannot be used for oils, greases, granulates, or bulk material.
The sensor supports switching signal, analog signal, and IO-Link outputs.