Owners manual for iCool Compact Series 3 ice bath chillers: setup, hoses, Wi-Fi, cold and hot settings, operation, water flow fixes and specifications.
This is the iCool Compact Series 3 Owners Manual for the Compact range of ice bath chilling and heating machines, covering the Compact Cool, Compact Dual Temp, Compact XP, Compact XP Dual Temp and Compact Iceman models. It opens with an overview of what each model does and the key features of the range, including remote control from smart phones and computers and a 10 inch Full HD capacitive touch screen on Series 3 models.
The rest of the manual is a step-by-step setup and operation guide: connecting the water hoses and the circulation pump, connecting electric power to the machine and pump, using the touch screen controller and starting up. It then covers Wi-Fi set up, system settings, automatic operation, cold and hot settings, basic set up, water flow problems, troubleshooting, specifications for each model and warranty and support contact details.
| Cooling Power | 5000 Watts (Compact Cool, Compact Dual Temp); 7200 Watts (Compact XP, Compact XP Dual Temp); 7800 Watts (Compact Iceman) |
|---|---|
| Heating Power | Chill only (Compact Cool, Compact XP, Compact Iceman); 5000 Watts (Compact Dual Temp); 7100 Watts (Compact XP Dual Temp) |
| Run (& Max.) Power at 220 Volts | 5 Amps (12 Amps) Compact Cool; 6.5 Amps (13 Amps) Compact Dual Temp; 7.5 Amps (14 Amps) Compact XP, Compact XP Dual Temp and Compact Iceman |
| Run (& Max.) Power at 110 Volts | 10 Amps (20 Amp) Compact Cool; 13 Amps (26 Amps) Compact Dual Temp; 15 Amps (28 Amps) Compact XP and XP Dual Temp; 13 Amps (26 Amps) Compact Iceman |
| Heat Pump Type | Rotary (all models) |
| Earth Leak Safety Device | Yes, 30 Milliamps (all models) |
| Heating Exchanger | Titanium heat exchanger tank and titanium heat pump |
| Touch Screen | 10 inch High Definition colour LCD touch screen |
| Air Flow Capacity | Low noise 2000 Cubic Ft per Minute (Compact Cool); Low noise 3000 Cubic Ft per Minute (other models) |
| Weight | 32kg / 72 Lbs (Compact Cool); 36kg / 79 Lbs (Compact Dual Temp); 39kg / 85 Lbs (Compact XP, XP Dual Temp, Iceman) |
| Dimensions (H x W x D) | 24 x 19.5 x 9.5 centimeters (all models) |
| Recommended Pool Size | 200 to 400 litres (Compact Cool, Compact Dual Temp); 300 to 2000 litres (Compact XP, XP Dual Temp, Compact Iceman) |
Match the colours of the connectors as shown in the manual: GREEN to the TOP and RED to the BOTTOM.
It is either a 220 volt model or a 110 volt model; check the voltage on the name plate above the power IN socket and never connect the wrong voltage.
Yes, but the water pump must be connected to the special socket on the machine, and pumps exceeding 1000 watts must not be used.
The iCool attempts to clear it automatically 3 times, and if that fails the touch screen directs you on how to correct the issue.
iCool products are covered by a standard One Year Warranty; keep your proof of purchase details in a safe place.