Instruction and maintenance manual for Huahai Marine Signals HH-3, HR-3, HB-3, HLS-2/HL-2, HT-2 and HTP-2 marine distress signals.
The manual covers the HH-3 hand flare, HR-3 rocket parachute flare, HB-3 buoyant smoke signal, HLS-2 and HL-2 lifebuoy signals, and the HT-2 and HTP-2 line throwing appliances. For each item it gives stated performance figures such as color, burning or smoke duration, light intensity, size, or throwing distance, followed by operating steps and warnings.
Maintenance instructions specify a storage temperature of -30°C to +65°C and prohibit burning or heating. The line throwing appliance section also describes cleaning and oiling before storage and a firing procedure using a 15° to 25° elevation. This manual is written in Chinese.
| HH-3 flare color | Red |
|---|---|
| HH-3 burning time | ≥ 60 s |
| HH-3 light intensity | ≥ 15000 cd |
| HH-3 size | Φ25*173mm |
| HR-3 fired altitude | ≥300m |
| HR-3 flare color | Red |
| HR-3 average light intensity | ≥30000 cd |
| HR-3 burning time | ≥ 40 s |
| HR-3 size | Φ47*262mm |
| HB-3 smoke color | Orange |
| HB-3 smoke duration time | ≥ 3 min |
| HB-3 smoke obscuration | ≥70% |
| HB-3 size | Φ81*137mm |
| HLS-2 light intensity | ≥ 2cd |
| HLS-2 burning time | ≥ 2h |
| HLS-2 size | Ф190*132mm |
| HL-2 smoke color | Orange |
| HL-2 smoke duration time | ≥ 15min |
| HL-2 smoke obscuration | ≥70% |
| HL-2 size | Ф94*450mm |
| HT-2 throwing distance | ≥ 230m |
| HT-2 line breaking strength | ≥ 2KN |
| HT-2 deflection | ≤ 10% of range |
| HT-2 size | 280*345mm |
| HTP-2 pistol size | Φ52*450mm |
| Storage temperature | -30°C to +65°C |
Store the signals at temperatures from -30°C to +65°C.
The HH-3 hand flare burns for at least 60 seconds.
Use an elevation of 15° to 25° when aiming at the target.
Clean all parts and smear them with lub oil, and keep them in good condition before stowing.