Instruction manual for the HOPE NeoFlame Jet Gas Burner Type ASG, covering inspection, safety precautions, installation, operation, troubleshooting, and…
This document serves as an instruction manual for the HOPE NeoFlame Jet Gas Burner Type ASG. It provides essential information on product inspection, safety precautions, and detailed installation procedures including piping and equipment setup.
The guide also covers operational instructions such as preparation, ignition sequences, and adjusting combustion parameters like excess air ratio. Additionally, it includes sections for troubleshooting common issues, maintenance inspections of nozzles and tiles, and construction drawings. This manual is written in Japanese.
| Turn-down ratio | 10:1 |
|---|---|
| Combustion gas speed | 80 m/sec |
| Reference pressure (Gas) | 2~10 kPa |
| Reference pressure (Air) | 6 kPa |
Use approximately 5 times the furnace volume as the reference volume of air-purge.
Stop the combustion blower after the in-furnace temperature lowers to below 500 ℃to protect the nozzle.