About this manual

This document serves as an instruction manual for the HOPE NeoFlame Jet Gas Burner Type ASG. It provides essential information on product inspection, safety precautions, and detailed installation procedures including piping and equipment setup.

The guide also covers operational instructions such as preparation, ignition sequences, and adjusting combustion parameters like excess air ratio. Additionally, it includes sections for troubleshooting common issues, maintenance inspections of nozzles and tiles, and construction drawings. This manual is written in Japanese.

What's inside

  • Inspection
  • Precautions for safety
  • Installation
  • Flow Sheet
  • Operation
  • Adjusting
  • Extinguishing
  • Troubleshooting

Specifications

Turn-down ratio10:1
Combustion gas speed80 m/sec
Reference pressure (Gas)2~10 kPa
Reference pressure (Air)6 kPa

Frequently asked questions

What is the recommended air purge volume before ignition?

Use approximately 5 times the furnace volume as the reference volume of air-purge.

When should the combustion blower be stopped?

Stop the combustion blower after the in-furnace temperature lowers to below 500 ℃to protect the nozzle.

What is the maximum combustion pressure setting?

Set the pressure to 6kPa for maximum combustion.