HOERBIGER P20 Piezo-pneumatic Switch Valve Operating Instructions

Operating instructions for the intrinsically safe HOERBIGER P20 piezo-pneumatic switch valve, covering assembly, installation, start-up, and maintenance.


HOERBIGER P20 Piezo-pneumatic Switch Valve Operating Instructions - cover page
Brand
HOERBIGER
Category
Industrial Supply
Document type
User Manual
Language
English
Pages
28
File format
PDF
File size
9.2 MB
Published
13 October, 2026
Updated
13 October, 2026
MD5 checksum
165996362C3FB8802C2FDFB86B730F79

About this manual

This document provides operating instructions for the HOERBIGER P20 piezo-pneumatic switch valve, which is intrinsically safe according to ATEX standards. It covers safety instructions, product description, assembly, installation, start-up, service, transport, storage, troubleshooting, and disposal procedures. The valve is designed for controlling compressed air in pneumatic process flow controllers and process technology applications, including areas subject to explosion.

What's inside

  • Notes about using the operating instructions
  • Basic safety instructions
  • Product description
  • Assembly and installation
  • Start-up
  • Service
  • Transport and storage
  • Troubleshooting
  • Decommissioning and disposal

Specifications

Actuation typePiezoelectric pilot valve-controlled
DesignPiezo seat valve, not overlap-free
Nominal pressure6 bar
Min. working pressure1.5 bar
Max. working pressure8 bar
Nominal flow rate> 110 l/min
Storage temperature-40 to +80 °C
Ambient temperature-10 to +60 °C

Frequently asked questions

What is the intended use of the P20 valve?

The valve serves to control compressed air activated by actuators in the standard pneumatic range, especially in areas subject to explosion.

Can the device be maintained by the user?

No, repair work must be performed by the manufacturer, and users should not maintain the inner parts of the device.