This manual provides operation, installation, adjustment, and troubleshooting instructions for the Hartzell HC-H3YF-3LF reversible propeller.
The document serves as a comprehensive guide for the Hartzell HC-H3YF-3LF reversible propeller. It details the operational principles involving oil pressure from the governor, counterweights, and air pressure to manage pitch changes between low, high, and full reverse positions. Specific attention is given to safety constraints regarding RPM limits during reversal to prevent engine overspeeding.
No, do not shut off the engine with pitch in reverse as it will cause damage to the control mechanism.
The governor control must always be set to maximum RPM position, or forward.
Removing one 1/32 inch washer increases the RPM setting by 75.