Maintenance manual for the Geberit Monolith Plus Sanitary Module, covering safety instructions, troubleshooting, and repair procedures for qualified…
This document serves as a maintenance guide for the Geberit Monolith Plus Sanitary Module (Model 971.759.00.0(00)). It is intended exclusively for qualified professionals to perform repairs and maintenance on the device, which includes user detection, odor extraction, and orientation lighting features.
The manual provides detailed instructions for replacing key components such as the power supply unit (Netzteil), the cistern lid assembly (Spülkastendeckel), the actuator lever, and various valves. It also outlines troubleshooting steps for common issues like non-functioning flushes or weak odor extraction. This manual is written in German.
| Nominal Voltage | 100–240 V AC |
|---|---|
| Mains Frequency | 50–60 Hz |
| Operating Voltage | 12 V DC |
| Power Consumption | 15 W |
| Standby Power Consumption | < 0.5 W |
| Flow Pressure Range | 0.1–10 bar (10–1,000 kPa) |
| Flush Volume Factory Setting | 6 and 3 l |
| Odour Extraction Run-on Time | 2 min |
This product must only be maintained and repaired by qualified personnel (Fachkräfte).
The factory setting is 6 liters and 3 liters.
If the mains cable is damaged, it must be replaced by a qualified professional.