Foxboro 875CR COMMUNICATOR Series Intelligent Electrochemical Analyzer Product Specifications

Foxboro 875CR COMMUNICATOR Series analyzer measures contacting conductivity and resistivity with dual sensor inputs, dual alarms and 4-20 mA outputs.


Foxboro 875CR COMMUNICATOR Series Intelligent Electrochemical Analyzer Product Specifications - cover page
Brand
FOXBORO
Category
Analyzer
Document type
Product Leaflet
Language
English
Pages
20
File format
PDF
File size
3.1 MB
Published
09 November, 2026
Updated
09 November, 2026
MD5 checksum
19FFD933D4420A76CBFD37A6E31F9EF1

About this manual

The Foxboro 875CR is a microprocessor-based, line-powered intelligent analyzer in the COMMUNICATOR Series, used with Foxboro 871CR or 871CC sensors for either contacting conductivity or resistivity measurement. It is available as a panel mounted analyzer and a field mounted analyzer, the latter carrying NEMA 4X and IEC IP65 protection. Functions include measurement display, dual analog outputs, dual relay contacts and an RS-232 serial port for remote configuration.

The document describes menu-driven configuration with basic and advanced levels, dual sensor input in dual or redundant mode, an RS-232 port with an optional Windows-based configuration utility, and a choice of digital communications PWAs, starting with HART. Resistivity ranges are selectable from 0.2 kΩ •cm through 20 MΩ•cm and conductivity ranges from 0 to 1 µS/cm through 0 to 20 mS/cm, both temperature corrected.

What's inside

  • Features
  • Easy to Use
  • Dual Sensor Input
  • RS-232 Port and Windows-Based Configuration Utility
  • High Accuracy, Wide Rangeability
  • Choice of Digital Communications
  • Designed with Your Industry in Mind
  • Dual Alarms and Dual 4 to 20 mA Outputs

Specifications

MeasurementContacting conductivity or resistivity
Resistivity range0.2 kΩ•cm through 20 MΩ•cm (temperature corrected)
Conductivity range0 to 1 µS/cm through 0 to 20 mS/cm (temperature corrected)
Resistivity system accuracy±1.06% rms
Sensor compatibilityFoxboro 871CR and 871CC sensors
Analog outputsTwo independent, isolated 4 to 20 mA outputs
Alarm relaysTwo independent, isolated alarm relays
Serial portBuilt-in, non-isolated RS-232
ProtectionNEMA 4X and IEC IP65 for field mounted analyzer
Event history logUp to 100 events
Application configurationsUp to 3 sets stored
StandardsUSP23/24 compliant

Frequently asked questions

Which sensors can be used with the Foxboro 875CR analyzer?

It is compatible with Foxboro 871CR and 871CC sensors for contacting conductivity or resistivity measurement.

How many sensors can be connected to the analyzer?

Either one or two contacting type sensors can be connected, and with two sensors the analyzer can be set to dual or redundant mode.

What conductivity and resistivity ranges does the 875CR support?

Resistivity ranges are selectable from 0.2 kΩ•cm through 20 MΩ•cm and conductivity ranges from 0 to 1 µS/cm through 0 to 20 mS/cm, both temperature corrected.

What digital communications protocol does the 875CR offer?

At initial product release, Foxboro offers a digital communications PWA for the HART communications protocol.