FMH Conveyors BestFlex BFP 1.5 and BFP 1.9 Conveyor System Operator's Manual

Operator's manual for the FMH Conveyors BestFlex BFP 1.5 and BFP 1.9 conveyor system, covering specifications, installation, maintenance and troubleshooting.


FMH Conveyors BestFlex BFP 1.5 and BFP 1.9 Conveyor System Operator's Manual - cover page
Brand
FMH Conveyors
Category
Other
Document type
User Manual
Language
English
Pages
35
File format
PDF
File size
936 KB
Published
16 November, 2026
Updated
16 November, 2026
MD5 checksum
9350E96DE4D916E7CBD27B92FD37F96D

About this manual

FMH Conveyors operator’s manual for the BestFlex BFP 1.5 and BFP 1.9 conveyor system. It gives standard product specifications, application guidelines, installation and assembly steps, maintenance procedures, troubleshooting, wiring and schematic information, parts lists and drawings, and recommended spare parts.

The manual also covers product options including the Interface Kit, Package Stop Kit, Indexing Kit, Side Rail Kit, PowerTrax and Split Kit. Safety and service instructions, warranty details and daily maintenance checks are included.

What's inside

  • Standard Product Specifications
  • Application Guidelines
  • Installation and Assembly Instructions
  • Maintenance Procedures
  • Troubleshooting
  • Wiring Diagram: Standard Power Unit
  • Parts List and Drawings
  • Recommended Spare Parts List
  • Interface Kit
  • PowerTrax

Specifications

Conveyor bed width18, 24, 30 in (457, 610, 762 mm)
Load capacity per linear foot100 lb (45.5 kg)
Roller diameterBFP 1.5: 1.5 in (38.1 mm); BFP 1.9: 1.9 in (48.26 mm)
Product travel speed0-120 ft/min (36.58 m/min)
Adjustable conveyor heightBFP 1.5: 31 ½ to 44 ½ in (800 to 1,130 mm); BFP 1.9: 28 ½ to 37 ½ in (724 to 946 mm)
Belt materialPolyurethane
Voltage120VAC
Current.85 Amps per motor
Drive motor1/8 HP rated
Noise level at conveyor bed levelApprox. 70 dB

Frequently asked questions

What is the conveyor load capacity?

The conveyor is rated at 100 pounds per linear foot on a level surface.

What should I know about the Emergency Stop push-buttons before running the conveyor?

A depressed Emergency Stop push-button prevents the conveyor from running, so release all E-stop buttons before operation.

How is the conveyor speed adjusted?

Adjust the speed with the potentiometer on the DC Variable Speed Drive located near the middle of the conveyor.

When should the DC motor brushes be replaced?

The brush should be replaced if it measures 0.125 inches or less.

Download PDF (936 KB)