The Fluke PRO3000 Toner and Probe is designed to help identify cables, wires, and wire pairs by transmitting a signal through the toner and tracing it with the probe. The toner emits constant or alternating tones, and the probe detects them with an amplified speaker. Safety precautions are emphasized, including avoiding use with wet equipment or AC voltage. The guide covers installation of batteries, probe operation, and tracing techniques including SmartTone™ for positive identification of wire pairs. The device supports up to 10 miles of 24 AWG twisted pair and has a SmartTone range of 2 miles. This manual is written in Chinese.

What's inside

  • Safety Information
  • Installing Batteries
  • The PRO3000 Probe
  • The PRO3000 Toner
  • Tracing Cables
  • Tracing Pairs
  • SmartTone Positive Identification

Specifications

Maximum Voltage60 Vdc
Tone RangeUp to 10 miles (16 km) of 24 AWG twisted pair
SmartTone Range2 miles (3.3 km)

Frequently asked questions

How do I install batteries in the PRO3000 toner?

Use only 9 volt alkaline batteries (not included). Open the battery compartment with a screwdriver to insert a new battery. Properly attach the connection wires and close the compartment. Do not over tighten the screw.

What does the PRO3000 Toner and Probe help you do?

It helps you identify cables, wires, and wire pairs.

What is the maximum voltage allowed across the test leads?

The maximum voltage allowed across the test leads is 60 Vdc in toner and polarity modes.