The Fluke 87V MAX is a True-rms digital multimeter with temperature measurement, low-pass filter, and MIN/MAX recording, rated for CAT III 1000 V and CAT IV…
The Fluke 87V MAX is a handheld True-rms digital multimeter designed for industrial electrical troubleshooting. It measures AC/DC voltage, AC/DC current, resistance, capacitance, frequency, duty cycle, and temperature via a type-K thermocouple. The meter features a 6000-count display with a 33-segment bargraph, automatic power-off, Input Alert™ for incorrect lead placement, and selectable power-up options such as low-pass filter, Zoom mode, and Smooth mode. It includes MIN/MAX recording, AutoHOLD, and relative modes for advanced measurement capture.
The meter is safety rated to IEC 61010-1 Pollution Degree 2 and IEC 61010-2-033 for CAT III 1000 V and CAT IV 600 V environments. It operates from -15 °C to 55 °C, is powered by three AA alkaline batteries providing up to 800 hours of typical use, and meets IP67 ingress protection. The unit weighs 1.14 lb (517 g) and measures 1.8 x 3.7 x 7.7 in (4.6 x 9.4 x 19.7 cm).
| Maximum voltage to earth ground | 1000 V rms |
|---|---|
| Fuse protection (mA/μA inputs) | 0.44 A, 1000 V, IR 10 kA |
| Fuse protection (A input) | 11 A, 1000 V, IR 17 kA |
| Display resolution | 6000 counts (19,999 in high-resolution mode) |
| Bargraph | 33 segments, 40 updates/sec |
| Operating temperature | -15 °C to 55 °C |
| Safety rating | CAT III 1000 V, CAT IV 600 V per IEC 61010-2-033 |
| Battery type | 3 × AA alkaline (IEC LR6) |
| Battery life | 800 hours typical without backlight |
| Ingress protection | IP67 per IEC 60529 |
The maximum voltage between any terminal and earth ground is 1000 V rms.
It meets CAT III 1000 V and CAT IV 600 V per IEC 61010-2-033.
It uses three AA alkaline batteries (IEC LR6).
Typical battery life is 800 hours without backlight using alkaline batteries.