Falcon E600 Rise and Fall Grill user, installation and servicing instructions covering setup, operation, cleaning and maintenance for professional use.
This manual provides user, installation and servicing instructions for the Falcon E600 Rise and Fall Grill, part of the F900 series. It is intended for professional use by qualified persons and includes safety information for installation and operation.
The document covers positioning and mains electrical connection, grill cooking and hold modes, user interface controls, program setting, switching off, and routine cleaning and maintenance of stainless steel parts.
| Electrical rating | 4.5kW |
|---|---|
| Electrical supply voltage | 400V 3N~ 50/60hz |
| Required electrical supply | 32A |
| Single phase supply | 19.56A |
| Clearance from rear wall | at least 50mm |
The electrical rating is 4.5kW.
It requires 400V 3N~ 50/60hz.
Clean with warm, soapy water, rinse thoroughly and dry with care; do not use products containing chlorine.
Check that voltage and frequency on the rating plate match the electrical supply system.