EXFO OmniCure 2000 Series UV/Visible Light Spot Curing System Product Leaflet

The EXFO OmniCure 2000 Series UV/visible light spot curing system offers 200 W lamp output up to 30 W/cm², 2000‑hour lamp life, Intelli‑Lamp cooling, and…


EXFO OmniCure 2000 Series UV/Visible Light Spot Curing System Product Leaflet - cover page
Brand
EXFO
Category
Other
Document type
Product Leaflet
Language
Chinese
Pages
4
File format
PDF
File size
808 KB
Published
06 October, 2026
Updated
06 October, 2026
MD5 checksum
7A06FC2EE46F18E76E2DA68DD3B01589

About this manual

The OmniCure 2000 Series is a smart UV/visible light spot curing system that uses a 200 W lamp to deliver up to 30 W/cm² of radiant power. It features Intelli‑Lamp® technology for lamp cooling and lifetime tracking, and a closed‑loop feedback system that automatically maintains the selected light intensity for consistent results.

The system can be calibrated with an optional R2000 light meter via wireless or serial communication, and it supports PLC or PC control through a 15‑pin I/O port. Optional band‑pass filters allow wavelength customization for a wide range of applications, including non‑stick surface curing of acrylic resins. The unit complies with CE, IEC, Canadian and US standards and includes safety features such as over‑heat protection and password lock. This manual is written in Chinese.

What's inside

  • 功能
  • 优点
  • 光传输
  • 灵活的光谱输出
  • 规格
  • 安全注意事项

Specifications

Dimensions (L×W×H)33.8 cm × 18.0 cm × 20.1 cm
Weight9.9 lb (4.5 kg)
Lamp power200 W
Maximum output intensity30 W/cm²
Lamp lifetime guarantee2000 hours
Standard wavelength range320‑500 nm
Optional wavelength ranges250‑450 nm, 365 nm, 320‑390 nm, 400‑500 nm, 250‑600 nm
Power input100‑120 VAC / 200‑240 VAC, 50/60 Hz
Pre‑heat time4 minutes (typical)
Control interface15‑pin I/O port

Frequently asked questions

What is the guaranteed lamp lifetime?

The lamp is guaranteed to last 2000 hours.

How can the system be calibrated for light intensity?

It can be calibrated using the optional R2000 light meter via wireless or serial communication.

What are the power input requirements?

The unit operates on 100‑120 VAC or 200‑240 VAC at 50/60 Hz.

Can the output wavelength be customized?

Yes, optional band‑pass filters allow selection of specific wavelength ranges for particular applications.