Espar Airtronic D2/D4 service manual covering system overview, diagnostics, visual inspection, maintenance, troubleshooting, repair, service information…
This Espar Airtronic D2/D4 Diagnostic and Repair Manual supports service technicians and end users in North America. It covers system operation, diagnostic devices such as EDITH PC diagnostics and the Digi-Diagnostic Tool, visual inspection procedures, maintenance, troubleshooting and repair, service information, and parts breakdown.
The manual applies to the Espar Airtronic D2 heater and D4 model, with instructions for fault code reading and clearing, fuel pump angle checks, combustion exhaust inspection, and component replacement using the unit serial number. It is not applicable to marine installations.
| Fuel pump angle | Between 15 and 35 degrees |
|---|---|
| Combustion exhaust extension past rear of cab | 1.5 to 2.5 inch |
| Combustion exhaust bend angle | At least 45 degree angle |
| Condensation drain hole size | 1/8th inch |
EDITH PC based diagnostics and the Digi-Diagnostic Tool or Digi-Controller.
While in diagnostic mode, push and hold both arrow buttons until “EE” is displayed on the screen.
No, the installation instructions and standards described in this document are not applicable to marine installations.