This guide provides quick installation and programming instructions for the Erreka VIVO-M101(M) gate control board, including wiring, DIP switch settings…
This document serves as a quick reference guide for the Erreka VIVO-M101(M) gate control board. It summarizes the full installation manual, covering electrical cabling requirements, general connections, and programming procedures for various operating modes. Users are advised that the options described apply to firmware version V2.00 or later available on the Erreka website.
| Power Supply (VIVO-M101) | 230Vac/50Hz |
|---|---|
| Power Supply (VIVO-M101M) | 125Vac/60Hz |
| Motor Fuse (VIVO-M101) | 2,5A |
| Electronic Fuse (VIVO-M101) | 0,5A |
| Output Fuse | 24Vac (315mA) |
| Main Power Supply Wire Section | 3x1.5mm2 |
| Photocells Wire Section | 2x0.5mm2 / 4x0.5mm2 |
The options and functions described are applicable from firmware version V2.00 or later.
Check operation using the mini-pushbuttons PUL1 (close) and PUL2 (open).
DL3 lights up to show that programming mode is enabled.
DIP8 enables the soft stop function for operators without a mechanical absorber.