Epson Toyocom RX-4801 SA/JE Real Time Clock Module Datasheet

The Epson Toyocom RX-4801 SA/JE real‑time clock module datasheet details its 32.768 kHz DTCXO, serial interface, pin functions, electrical characteristics…


Epson Toyocom RX-4801 SA/JE Real Time Clock Module Datasheet - cover page
Brand
Epson Toyocom
Category
Other Electronics
Document type
Datasheet
Language
English
Pages
2
File format
PDF
File size
676 KB
Published
05 October, 2026
Updated
05 October, 2026
MD5 checksum
614D8C1E83E75E52B12DC71AA12BFF3C

About this manual

The RX-4801 SA/JE is a real‑time clock module with a built‑in 32.768 kHz DTCXO offering high stability and a 4‑wire serial interface. It provides calendar, alarm, timer functions and selectable output frequencies of 32.768 kHz, 1024 Hz or 1 Hz.

The datasheet lists the pin assignments, electrical characteristics such as interface voltage (1.6‑5.5 V), temperature‑compensated voltage (2.2‑5.5 V), operating temperature range (‑40 °C to +85 °C) and current consumption, as well as product numbers for the SA and JE variants.

What's inside

  • Overview
  • Pin Function
  • Specifications
  • Electrical Characteristics
  • Product Number

Specifications

Clock voltage VCLK1.6 V min – 5.5 V max (typ 3.0 V)
Operating temperature-40 °C to +85 °C
Frequency stability UA (0 °C to +40 °C)±1.9 × 10⁻⁶
Current consumption (normal mode, VDD=5 V)1.2 µA min – 3.4 µA max

Frequently asked questions

What output frequencies can the module generate?

The module can output 32.768 kHz, 1024 Hz or 1 Hz, selectable via the FOUT pin.

What type of interface does the module use?

It uses a 4‑wire serial interface with an operating voltage range of 1.6 V to 5.5 V.

What is the operating temperature range of the module?

The module operates from –40 °C to +85 °C.

What is the function of the /INT pin?

The /INT pin provides an open‑drain interrupt output.

Download PDF (676 KB)