EMOD EeEA/EeDA/EeDG 56–225 Series Explosion-Proof Three-Phase and Single-Phase Motors Operating Manual

Operating manual for EMOD EeEA/EeDA/EeDG 56–225 series explosion-proof three-phase and single-phase motors, covering safety, transport, installation and…


EMOD EeEA/EeDA/EeDG 56–225 Series Explosion-Proof Three-Phase and Single-Phase Motors Operating Manual - cover page
Brand
EMOD
Category
Explosion Proof Motors
Document type
User Manual
Language
German
Pages
28
File format
PDF
File size
3.5 MB
Published
16 November, 2026
Updated
16 November, 2026
MD5 checksum
55E3E9CCDB5744C62D6003F76C035B12

About this manual

This operating manual, edition 08/2018 (Art.-no. 118628 / Ident.-no. K.51.821.101), applies to EMOD three-phase motors in type of protection Increased Safety “eb” and single-phase motors in type of protection Increased Safety “eb” with a capacitor in type of protection Powder Filling “qb”. It covers frame sizes 56 to 225 and type series EeEA 56 … EeDA 56 – 112 … EeDG 90 – 225, according to EN 60079-0:2012+A11:2013, EN 60079-7:2015+A1:2018, EN 60079-5:2015 and Directive 2014/34/EU (ATEX).

The manual contains general notes and safety information, transport and storage instructions, insulation resistance checks, and mounting and commissioning guidance. It also includes an overview of the EMOD product range, listing series such as 820, 821, 821/IE, 822, 824, 825, 826, 829, 831, 835, 836, 837 and 838 with their IP degrees of protection and power ranges. This manual is written in German.

What's inside

  • General Notes
  • Safety
  • Explosion-Protected Areas
  • Equipment Group II Category 2G (EPL Gb)
  • Transport and Storage
  • Checking the Insulation Resistance
  • Installation and Commissioning
  • Fastening Motors
  • Condensate Drain Holes
  • Balancing

Specifications

Frame sizes56 to 225
Type seriesEeEA 56 … EeDA 56 – 112 … EeDG 90 – 225
Ex marking (three-phase motors)0123 II 2G Ex eb IIC T1, T2, T3 or T4 Gb
Ex marking (single-phase motors with capacitor)0123 II 2G Ex eb qb IIC T1, T2, T3 or T4 Gb
StandardsEN 60079-0:2012 + A11:2013; EN 60079-7:2015 + A1:2018; EN 60079-5:2015
Directive2014/34/EU (ATEX)
Ambient temperature in explosive areas−20 °C to +60 °C
Pressure in explosive areas0.8 bar to 1.1 bar
Standard ambient/cooling medium temperature for installation−20 °C to 40 °C
Special ambient/cooling medium temperature−40 °C to 65 °C

Frequently asked questions

What frame sizes does this manual cover?

It covers frame sizes 56 to 225.

Which type series are covered?

The type series are EeEA 56 … EeDA 56 – 112 … EeDG 90 – 225.

When must the insulation resistance of the winding be checked?

Before commissioning after long storage or a standstill of more than 6 months.

What is the Ex marking for the three-phase motors?

0123 II 2G Ex eb IIC T1, T2, T3 or T4 Gb.

Download PDF (3.5 MB)

More EMOD Manuals