ELESA MM-BL-NK / MM-BI-NK / MM-BC-NK Pneumatic Fastening Clamps Operating Instructions

Operating instructions for ELESA MM-BL-NK, MM-BI-NK and MM-BC-NK pneumatic fastening clamps, covering safety, mounting, force adjustment and maintenance.


ELESA MM-BL-NK / MM-BI-NK / MM-BC-NK Pneumatic Fastening Clamps Operating Instructions - cover page
Brand
Elesa
Category
Other
Document type
User Manual
Language
Italian
Pages
24
File format
PDF
File size
307 KB
Published
09 November, 2026
Updated
09 November, 2026
MD5 checksum
185CB5CB69338F6B93F9273E1ACC0488

About this manual

The document is the operating instructions for ELESA pneumatic fastening clamps in the MM-BL-NK, MM-BI-NK and MM-BC-NK series. It is intended for process engineers, plant and machine designers, and assembly and maintenance personnel.

It describes the available sizes 20, 32, 40 and 50, explains that the size refers to the piston diameter, and covers safety warnings, mounting and commissioning, operating-state sensing with the MM-SI proximity sensor, clamping-force adjustment, automatic locking checks, maintenance and pneumatic kit disassembly/mounting. This manual is written in Italian.

What's inside

  • Safety warnings
  • Intended use and field of application
  • Product description
  • Safety
  • Mounting and commissioning
  • Operating and switching state sensing
  • Clamping force adjustment
  • Automatic locking
  • Maintenance
  • Pneumatic kit disassembly/mounting

Specifications

Available sizes20, 32, 40 and 50
Size referencePiston diameter of the pneumatic drive cylinder
Normal operating pressure6 bar
Maximum operating pressure10 bar
Maximum ambient temperature for MM-SI sensor80 °C
Maximum permitted torque, size 201.00 Nm
Maximum permitted torque, size 321.25 Nm
Maximum permitted torque, size 401.50 Nm
Maximum permitted torque, size 503.00 Nm

Frequently asked questions

What sizes are available for the pneumatic fastening clamps?

The clamps are available in sizes 20, 32, 40 and 50. The size refers to the piston diameter of the pneumatic drive cylinder.

What is the normal working pressure of the clamps?

The normal working pressure is 6 bar for all sizes.

What is the maximum operating pressure?

The operating pressure must not exceed 10 bar.

How are the operating and switching states displayed?

They can be displayed using the MM-SI proximity sensor.