The Electro-Sensors ST420 manual provides installation, wiring, specifications, and usage instructions for the 4‑20 mA shaft speed sensor.
The ST420 is a 4‑20 mA analog output shaft speed sensor that works with a pulse target (magnetic disk or pulse ring) to generate a magnetic pulse signal proportional to shaft speed. It integrates a magnetic pulse detector, signal processing, and a two‑wire power loop inside an M18×1 stainless‑steel housing.
The manual covers product overview, installation steps, wiring diagrams (including intrinsically safe wiring), technical parameters, and compatibility information. It also provides guidance on sensor head alignment, gap adjustment, and cable connections. This manual is written in Chinese.
| Supply voltage (Vin) | 8‑30 Vdc (nominal 24 Vdc) |
|---|---|
| Maximum voltage | 30 Vdc |
| Maximum current | 150 mA |
| Sensor head gap | 1/4" (±1/8") |
| Operating temperature | -20 °C to +85 °C |
| Accuracy at 25 °C | ±0.25 % |
| Accuracy outside temperature range | ±0.50 % |
| Output response time | < 9 ms |
| Cable type | Alpha 5092C shielded 2×24 AWG |
| Protection class | Class II (E,F,G) Div.1 |
| Dimensions | Length 80 mm (3.15 in), Diameter 18 mm (0.71 in) |
Align the arrow on the sensor head with the line connecting the center of the magnetic poles of the pulse target.
Adjust the gap to 1/4 in (6.35 mm).
The sensor operates from 8 Vdc to 30 Vdc, with a nominal loop voltage of 24 Vdc.
I = 4 mA + 16 mA × (f‑fmin)/(fmax‑fmin).