The Eipl RM4500 is a rugged, industrial dehumidifier designed for a wide range of applications. It features a high-efficiency rotary compressor, an integral pump-out system, and a programmable digital humidistat for precise humidity control. The unit utilizes a reverse cycle defrost system to operate effectively in low-temperature environments.

What's inside

  • Introduction
  • Specifications
  • Operation
  • Routine Service
  • Repairs
  • Troubleshooting
  • Spare Parts List
  • Warnings

Specifications

Height44" (1115mm)
Width25" (625mm)
Depth28" (710mm)
Weight170 lbs (77 Kg)
Airflow350 CFM (600 M3/hr)
Power Supply110V/ 60Hz/ 1 ph
Operating Range33° F – 95° F
RefrigerantR-407c (22.9 oz)

Frequently asked questions

How do I set the desired humidity level?

Press the 'S' button to access the set point, use the up or down buttons to change the level, and press 'S' again to save.

When does the defrost cycle occur?

The unit operates a defrost cycle approximately every 20 minutes when running in an ambient temperature of less than 59° F.

How often should I check the refrigerant charge?

To check the charge, run the unit for 15 minutes and observe the evaporator coil; it should be evenly frost coated.