Battery-powered Ei Ei206D carbon monoxide alarm with digital display; installation, testing, maintenance, troubleshooting and technical specifications.
The Ei Ei206D is a battery-powered carbon monoxide alarm with a digital display. The leaflet covers installation, placement, testing, maintenance, limitations, troubleshooting and technical specifications.
It describes CO alarm response levels, memory and reset functions, sensor replacement, and actions to take when the alarm sounds.
| Operating Temperature | -10°C to 40°C |
|---|---|
| Humidity Range | 15% to 95% R.H. (non-condensing) |
| Audible Alarm | 85dB(A) at 3m minimum |
| Self Diagnostics | Horn beep and amber fault light flashes every 40 seconds if a sensor fault is found. |
| Tamperproof | Locking screw supplied |
| Digital Display | Range 30-300 ppm CO; resolution 5 ppm CO |
| Sensor Replacement | Amber light flashes every 45 seconds after 6 years |
| Sensor Replacement Limit | The sensor can only be replaced once |
Open doors and windows, turn off fuel appliances, evacuate, get medical help, contact the fuel supplier, and do not re-enter or reuse appliances until checked.
Test the unit weekly by pressing the test/hush button.
Replace the battery yearly, or when the unit beeps every 40 seconds, or when CP is on the display.
A depleted battery.