ECOTOP SuperStar ultra-sensitive ECL chemiluminescence reagent kit for HRP-labeled antibody Western blot and nucleic acid hybridization.
ECOTOP SuperStar is an ultra-sensitive ECL chemiluminescence reagent kit for detecting antibodies labeled directly or indirectly with horseradish peroxidase (HRP) and their associated antigens. It is used for Western blot with HRP-labeled antibodies and nucleic acid hybridization with HRP-labeled probes.
The kit is supplied as 50 ml of Solution A and 50 ml of Solution B (EK-5008-100 ml) and is stored at 4°C protected from light for 12 months. The instructions describe preparing a 1:1 working solution, incubating the membrane, and exposing X-ray film, along with handling notes. This manual is written in Chinese.
| Package | EK-5008-100 ml: SuperStar ECL Solution A 50 ml, Solution B 50 ml, 1 instruction sheet |
|---|---|
| Storage | 4°C, protected from light, 12 months |
| Sensitivity | Femtogram-level detection on nitrocellulose or PVDF membranes |
| Signal stability | Stable signal during the key 4-hour period; up to 24 hours of light output under optimal conditions |
| Working solution stability | 8 hours |
| Kit stability | 1 year at 4°C |
| Primary antibody | 0.2-1.0 μg/mL (1:1000 to 1:5000 from 1 mg/mL stock) |
| Secondary antibody | 10-50 ng/mL (1:20,000 to 1:100,000 from 1 mg/mL stock) |
Mix Solution A and Solution B in a 1:1 ratio; use immediately, although it can still be used after several hours at room temperature with slightly reduced sensitivity.
Fully immerse the membrane in working solution and incubate at room temperature for 2 minutes before exposure.
Steps 1-5 can be performed under daylight, but prolonged exposure of the reagent to strong light may slightly reduce sensitivity.
For most imported antibodies, start at 1:1000-1:4000 for the primary antibody and 1:2000-1:5000 for the secondary antibody.