The ECOsmarte X Pool System User Manual provides installation, start‑up, water testing, maintenance and troubleshooting instructions.
This manual covers everything needed to install and operate the ECOsmarte X Pool System, including placement of the electrode chamber, wiring of the electronic box, and required pool turnover rates. Detailed start‑up steps explain how to achieve the correct copper residual and pH balance during the first weeks of operation.
Later sections describe routine water testing, regular maintenance, troubleshooting common problems, and a list of compatible or incompatible chemicals and accessories. Warranty information and contact details for ECOsmarte support are also included.
| Copper residual | 0.4‑0.7 ppm |
|---|---|
| pH range | 6.8‑7.2 |
| Minimum calcium hardness | 400 ppm |
| Pool turnover requirement | 1.5‑2 complete turnovers during daylight hours |
| Minimum filter size | 300 lb |
| Recommended pump power | 1.0‑2.0 HP |
The pool water pH should be kept between 6.8 and 7.2.
A copper residual of 0.4 to 0.7 ppm is needed for the system to work properly.
The system requires 1.5 to 2 complete turnovers during daylight hours.
A minimum filter of 300 lb is required.