Operating instructions for the ebm-papst R3G450-AZ30-01 built-in air conveying device, covering safety, proper use, technical data and connection.
ebm-papst R3G450-AZ30-01 is described in this document as a built-in device for conveying air. The operating instructions cover safety regulations and notes, proper use, technical data, connection and start-up, integrated protective functions, and maintenance, malfunctions, possible causes and remedies.
The safety section addresses hazard levels, staff qualification, electrical voltage, mechanical movement, emissions, hot surfaces, storage and disposal. Technical data includes a product drawing with mounting and cable-gland details, while proper use limits operation to earthed-neutral power systems and air with a density of 1.2 kg/m3.
| Air density for moving air | 1.2 kg/m3 |
|---|---|
| Cable diameter (small gland) | min. 4 mm, max. 10 mm |
| Tightening torque (small gland) | 4+0.6 Nm |
| Cable diameter (large gland) | min. 9 mm, max. 16 mm |
| Tightening torque (large gland) | 6+0.9 Nm |
| Tightening torque | 3.5+0.5 Nm |
The device may only be used in power systems with earthed neutral (TN/TT power systems).
Proper use includes moving air with a density of 1.2 kg/m3.
ebm-papst recommends storing the device for a maximum of one year.
The document specifies tightening torques of 4+0.6 Nm, 6+0.9 Nm and 3.5+0.5 Nm.